Explanation:
SPA platform type load cell is capable measuring weights from a single point. It offers a high level of accuracy and features an internal thermal compensation that corrects output drifts due to ambient temperature variations. It is resistant to momentum forces.
With its corrosion-resistant aluminum construction and its strain gauge area isolated with a special chemical material, the SPA load cells are protected against water in accordance with IP55 standards. Suitable for platform sizes of up to 80 x 80 cm, SPA load cells are produced in two different capacities (200 and 600 kg) and they may be mounted in the center of or under the platform. These platform type scales with one load cell find application in conveyor scales, roller scales and process weighing applications.
Models:
Model | Capacities | Minumum Division | Maximum Overload Capacity |
---|---|---|---|
SPA | 80 kg | 16 g | 80 kg |
SPA | 150 kg | 30 g | 150 kg |
SPA | 300 kg | 60 g | 300 kg |
Specifications:
Maximum capacities (Emax) | kg | 80,150,300 |
Accuracy (OIML R60) | C1 C3 | |
Maximum number of verification intervals () | 1000 3000 | |
Minimum verification interval () | Emax/5000 Emax/5000 | |
Combined error | % | ≤ ±0.05 ≤ ±0.02 |
Creep error over 30 min. (DR) | % Emax | 0.012 |
Minimum load | % Emax | 0 |
Maximum safe overload | % Emax | 100 |
Maximum safe sideload | % Emax | 100 |
Ultimate load | % Emax | 150 |
Stretching (Emax) | mm | ≤0.7 |
Maximum excitation voltage (Umax) | V | 10 |
Rated output (Cn) | mV/V | 2 ±0.1% |
Zero balance | %Cn | ≤ ±1.0 |
Input Resistance | Ω | 409±6 |
Output Resistance | Ω | 350 ±3.5 |
Insulation resistance | MΩ | ≥500 |
Compensated temperature range | °C | -10...+40 |
Operating temperature range | °C | -40...+80 |
Load cell material | Aluminum | |
Sealing (EN60529) | IP55 | |
Cable length | m | 2 |
Cable diameter | mm | 5.5 |
Weight | kg | 0.55 |
Package dimensions / weight | cm/kg | 7x18x12 / 0.6 |