Explanation:
The STCS bending beam load cell has been developed for tension and compression type weight and force measurement applications.
The STCS load cell finds application in tank weighing applications, hopper scales, electromechanical scales, tension-tear test devices, process weighing applications and other similar systems. It offers a high level of accuracy and features an internal thermal compensation that corrects output drifts due to ambient temperature variations. Stainless steel STCS load cells are resistant to all types of weather conditions and protected to IP66 standards.
Models:
Model | Capacities | Minumum Division | Maximum Overload Capacity |
---|---|---|---|
STCS 50 | 50 kg | 5 g | 75 kg |
STCS 100 | 100 kg | 10 g | 150 kg |
STCS 200 | 200 kg | 20 g | 300 kg |
STCS 500 | 500 kg | 50 g | 750 kg |
Specifications:
Maximum capacities (Emax) | kg | 50,100,200,500 |
Accuracy (OIML R60) | C1 C3 | |
Maximum number of verification intervals () | 1000 3000 | |
Minimum verification interval () | Emax/5000 Emax/10000 | |
Combined error | % | ≤ ±0.05 ≤ ±0.02 |
Creep error over 30 min. (DR) | % Emax | 0.007 |
Minimum load | % Emax | 0 |
Maximum safe overload | % Emax | 150 |
Maximum safe sideload | % Emax | 100 |
Ultimate load | % Emax | 200 |
Stretching (Emax) | mm | ≤ 0.4 |
Maximum excitation voltage (Umax) | V | 15 |
Rated output (Cn) | mV/V | 2 ±0.1% |
Zero balance | %Cn | ≤ ±1.0 |
Input Resistance | Ω | 385 ±20 |
Output Resistance | Ω | 350 ±3 |
Insulation resistance | MΩ | ≥500 |
Compensated temperature range | °C | -10...+40 |
Operating temperature range | °C | -40...+80 |
Load cell material | Stainless Steel | |
Sealing (EN60529) | IP66 | |
Cable length | m | 5 |
Cable diameter | mm | 5 |
Weight | kg | 0.5 |
Package dimensions / weight | cm/kg | 10x27x6 / 0.6 |